{"title":"Spectroscopy Detectors","description":"\u003cp\u003eSingle-point and array detectors for monochromator-based spectroscopy from UV to mid-infrared: silicon photodiodes, photomultiplier modules, room-temperature and TE-cooled InGaAs, PbS, liquid-nitrogen-cooled InSb and MCT detectors, InGaAs linear arrays and TE-cooled spectroscopy CCDs.\u003c\/p\u003e","products":[{"product_id":"dsi-series-silicon-photodetectors","title":"DSi Series Silicon Photodetectors, 200–1100 nm, 100 mm² Active Area","description":"\u003cdiv class=\"wq-pdp__lbtek-desc\"\u003e\n\u003cp\u003e\u003cem\u003eSilicon photodiode detectors that mount directly on monochromator slits for UV–NIR measurements at good light levels.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eDSi series detectors are rugged silicon photodiodes for measurements where a reasonable amount of light is collected. Each detector sits in a housing with a BNC signal connector and a mounting flange that attaches directly to the slit assembly of Omni-λ series monochromators. The DSi200 is UV-enhanced for 200–1100 nm, while the DSi300 is a blue-enhanced general-purpose version.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wq-pdp__lbtek-tips\"\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTwo versions: DSi200 UV-enhanced (200–1100 nm) and DSi300 blue-enhanced (350–1100 nm)\u003c\/li\u003e\n\u003cli\u003e100 mm² active area (Ø11.28 mm) on both models\u003c\/li\u003e\n\u003cli\u003eHousing with BNC signal connector and flange for direct mounting on Omni-λ series monochromator slits\u003c\/li\u003e\n\u003cli\u003eCurrent output; the ZAMP I-V transimpedance amplifier is recommended ahead of an oscilloscope or lock-in amplifier\u003c\/li\u003e\n\u003cli\u003eConnects to the DCS300PA data acquisition system without a separate preamplifier, as amplification is built in; with the DCS103 the ZAMP is recommended\u003c\/li\u003e\n\u003cli\u003eNEP of 4.5×10⁻¹³ W\/√Hz (DSi200) and 2.0×10⁻¹³ W\/√Hz (DSi300)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wq-pdp__lbtek-tips\"\u003e\n\u003ch3\u003eTypical Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUV, visible and NIR measurements with scanning monochromators\u003c\/li\u003e\n\u003cli\u003eTransmission, reflection and absorption spectroscopy\u003c\/li\u003e\n\u003cli\u003eSpectral characterization of light sources\u003c\/li\u003e\n\u003cli\u003eLock-in detection of chopped optical signals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wq-pdp__lbtek-tips\"\u003e\n\u003ch3\u003eModel Overview\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable style=\"border-collapse:collapse;width:100%;font-size:13px\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"border:1px solid #d0d7e2;padding:4px 6px;background:#f2f5f9;text-align:left\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d7e2;padding:4px 6px;background:#f2f5f9;text-align:left\"\u003eType\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d7e2;padding:4px 6px;background:#f2f5f9;text-align:left\"\u003eSpectral Range (nm)\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d7e2;padding:4px 6px;background:#f2f5f9;text-align:left\"\u003ePeak Wavelength (nm)\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d7e2;padding:4px 6px;background:#f2f5f9;text-align:left\"\u003ePeak Responsivity (A\/W)\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d7e2;padding:4px 6px;background:#f2f5f9;text-align:left\"\u003eRise Time (µs)\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d7e2;padding:4px 6px;background:#f2f5f9;text-align:left\"\u003eShunt Resistance (MΩ)\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d7e2;padding:4px 6px;background:#f2f5f9;text-align:left\"\u003eNEP (W\/√Hz)\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d7e2;padding:4px 6px;background:#f2f5f9;text-align:left\"\u003eJunction Capacitance at 0 V (pF)\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d7e2;padding:4px 6px;background:#f2f5f9;text-align:left\"\u003eMax. Operating Current at 0 V (mA)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003eDSi200\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003eUV-enhanced\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e200–1100\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e820\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e0.52\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e5.9\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e10 (min. 5)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e4.5×10⁻¹³\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e4500\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e0.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003eDSi300\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003eBlue-enhanced\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e350–1100\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e970\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e0.60 (min. 0.55)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e2\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003emin. 10\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e2.0×10⁻¹³\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e8800\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e10.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wq-pdp__lbtek-tips\"\u003e\n\u003ch3\u003eRelated Products\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/dingaas-series-room-temperature-ingaas-detectors\"\u003eDInGaAs Series\u003c\/a\u003e — Room-Temperature InGaAs Detectors\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/dingaas-te-series-te-cooled-ingaas-detectors\"\u003eDInGaAs-TE Series\u003c\/a\u003e — TE-Cooled InGaAs Detectors\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/dfield-nir-series-ingaas-linear-array-detectors\"\u003eDField-NIR Series\u003c\/a\u003e — InGaAs Linear Array Detectors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBrowse all: \u003ca href=\"\/collections\/lbtek-light-analysis-photodetection-spectroscopy-detectors\"\u003eSpectroscopy Detectors\u003c\/a\u003e · \u003ca href=\"\/collections\/lbtek-light-analysis-photodetection\"\u003ePhotodetection\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eModels: DSi200, DSi300\u003c\/strong\u003e · Contact WaveQuanta for a quote, configuration advice and lead time.\u003c\/p\u003e","brand":"WaveQuanta","offers":[{"title":"Default Title","offer_id":68106328047770,"sku":"DSi Series","price":0.0,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0734\/6156\/3546\/files\/wq-dsi-series-silicon-photodetectors-1.jpg?v=1794127866"},{"product_id":"dingaas-series-room-temperature-ingaas-detectors","title":"DInGaAs Series Room-Temperature InGaAs Detectors, 800–2600 nm, Ø3 mm","description":"\u003cdiv class=\"wq-pdp__lbtek-desc\"\u003e\n\u003cp\u003e\u003cem\u003eRoom-temperature InGaAs single-point detectors for near-infrared measurements from 0.8 to 2.6 µm.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eDInGaAs series detectors are room-temperature InGaAs photodiodes for the near-infrared range from 0.8 µm to 2.6 µm. The DInGaAs1700-R03M and DInGaAs2600-R03M share the same construction with a 3 mm diameter active area, and differ in spectral range: 800–1700 nm and 800–2600 nm respectively.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wq-pdp__lbtek-tips\"\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTwo models covering 800–1700 nm and 800–2600 nm\u003c\/li\u003e\n\u003cli\u003eØ3 mm active area on both models\u003c\/li\u003e\n\u003cli\u003eRoom-temperature operation, no cooling required\u003c\/li\u003e\n\u003cli\u003eMinimum peak responsivity of 0.9 A\/W (DInGaAs1700-R03M) and 1.1 A\/W (DInGaAs2600-R03M)\u003c\/li\u003e\n\u003cli\u003eCurrent output; an I-V transimpedance amplifier such as the ZAMP is recommended before an oscilloscope or lock-in amplifier\u003c\/li\u003e\n\u003cli\u003eCan be read directly by the DCS300PA data acquisition system, which has built-in amplification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wq-pdp__lbtek-tips\"\u003e\n\u003ch3\u003eTypical Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNear-infrared spectroscopy with scanning monochromators\u003c\/li\u003e\n\u003cli\u003eNIR photoluminescence measurements\u003c\/li\u003e\n\u003cli\u003eTransmission and absorption measurements from 0.8 to 2.6 µm\u003c\/li\u003e\n\u003cli\u003eLock-in detection of chopped NIR signals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wq-pdp__lbtek-tips\"\u003e\n\u003ch3\u003eModel Overview\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable style=\"border-collapse:collapse;width:100%;font-size:13px\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"border:1px solid #d0d7e2;padding:4px 6px;background:#f2f5f9;text-align:left\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d7e2;padding:4px 6px;background:#f2f5f9;text-align:left\"\u003eSpectral Range (nm)\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d7e2;padding:4px 6px;background:#f2f5f9;text-align:left\"\u003ePeak Responsivity, Min. (A\/W)\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d7e2;padding:4px 6px;background:#f2f5f9;text-align:left\"\u003eDark Current, Max. (nA)\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d7e2;padding:4px 6px;background:#f2f5f9;text-align:left\"\u003eD* (typ.)\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d7e2;padding:4px 6px;background:#f2f5f9;text-align:left\"\u003eNEP (typ.)\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d7e2;padding:4px 6px;background:#f2f5f9;text-align:left\"\u003eShunt Resistance\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d7e2;padding:4px 6px;background:#f2f5f9;text-align:left\"\u003eCapacitance (pF)\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d7e2;padding:4px 6px;background:#f2f5f9;text-align:left\"\u003eRise Time\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003eDInGaAs1700-R03M\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e800–1700\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e0.9\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e100\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e2.3×10¹²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e1.2×10⁻¹³\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e1.5 MΩ\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e800\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e100 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003eDInGaAs2600-R03M\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e800–2600\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e1.1\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e1000\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e4.1×10¹⁰\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e6.5×10⁻¹²\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e320 Ω\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e9000\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e1 µs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wq-pdp__lbtek-tips\"\u003e\n\u003ch3\u003eRelated Products\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/dsi-series-silicon-photodetectors\"\u003eDSi Series\u003c\/a\u003e — Silicon Photodetectors\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/dingaas-te-series-te-cooled-ingaas-detectors\"\u003eDInGaAs-TE Series\u003c\/a\u003e — TE-Cooled InGaAs Detectors\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/dfield-nir-series-ingaas-linear-array-detectors\"\u003eDField-NIR Series\u003c\/a\u003e — InGaAs Linear Array Detectors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBrowse all: \u003ca href=\"\/collections\/lbtek-light-analysis-photodetection-spectroscopy-detectors\"\u003eSpectroscopy Detectors\u003c\/a\u003e · \u003ca href=\"\/collections\/lbtek-light-analysis-photodetection\"\u003ePhotodetection\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eModels: DInGaAs1700-R03M, DInGaAs2600-R03M\u003c\/strong\u003e · Contact WaveQuanta for a quote, configuration advice and lead time.\u003c\/p\u003e","brand":"WaveQuanta","offers":[{"title":"Default Title","offer_id":68106328080538,"sku":"DInGaAs Series","price":0.0,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0734\/6156\/3546\/files\/wq-dingaas-series-room-temperature-ingaas-detectors-1.jpg?v=1794127870"},{"product_id":"dingaas-te-series-te-cooled-ingaas-detectors","title":"DInGaAs-TE Series TE-Cooled InGaAs Detectors, 800–2600 nm, -40 °C","description":"\u003cdiv class=\"wq-pdp__lbtek-desc\"\u003e\n\u003cp\u003e\u003cem\u003eTwo-stage TE-cooled InGaAs detectors for low-noise near-infrared measurements from 0.8 to 2.6 µm.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eDInGaAs-TE series detectors use two-stage thermoelectrically cooled InGaAs photodiodes for the 0.8–2.6 µm range. The DInGaAs1700-TE and DInGaAs2600-TE share the same construction with a 3 mm diameter active area; the sensor is held at -40 °C with ±0.5 °C stability by the ZTC temperature controller.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wq-pdp__lbtek-tips\"\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTwo models covering 800–1700 nm and 800–2600 nm\u003c\/li\u003e\n\u003cli\u003eTwo-stage TE cooling to -40 °C, temperature stability ±0.5 °C\u003c\/li\u003e\n\u003cli\u003eØ3 mm active area on both models\u003c\/li\u003e\n\u003cli\u003eTypical NEP of 3.2×10⁻¹⁵ (DInGaAs1700-TE) and 5.5×10⁻¹³ (DInGaAs2600-TE)\u003c\/li\u003e\n\u003cli\u003eCurrent output; the ZAMP I-V transimpedance amplifier is recommended before an oscilloscope, lock-in amplifier or the DCS103\u003c\/li\u003e\n\u003cli\u003eCan be read directly by the DCS300PA data acquisition system, which has built-in amplification\u003c\/li\u003e\n\u003cli\u003eIn cooled mode, operation requires the ZTC temperature controller\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wq-pdp__lbtek-tips\"\u003e\n\u003ch3\u003eTypical Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLow-light near-infrared spectroscopy\u003c\/li\u003e\n\u003cli\u003eNIR photoluminescence measurements\u003c\/li\u003e\n\u003cli\u003eTransmission and absorption measurements from 0.8 to 2.6 µm\u003c\/li\u003e\n\u003cli\u003eLock-in detection with scanning monochromators\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wq-pdp__lbtek-tips\"\u003e\n\u003ch3\u003eModel Overview\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable style=\"border-collapse:collapse;width:100%;font-size:13px\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"border:1px solid #d0d7e2;padding:4px 6px;background:#f2f5f9;text-align:left\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d7e2;padding:4px 6px;background:#f2f5f9;text-align:left\"\u003eSpectral Range (nm)\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d7e2;padding:4px 6px;background:#f2f5f9;text-align:left\"\u003ePeak Responsivity (A\/W)\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d7e2;padding:4px 6px;background:#f2f5f9;text-align:left\"\u003eD* (typ.)\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d7e2;padding:4px 6px;background:#f2f5f9;text-align:left\"\u003eNEP (typ.)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003eDInGaAs1700-TE\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e800–1700\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e0.9\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e8.4×10¹³\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e3.2×10⁻¹⁵\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003eDInGaAs2600-TE\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e800–2600\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e1.2\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e4.9×10¹¹\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e5.5×10⁻¹³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wq-pdp__lbtek-tips\"\u003e\n\u003ch3\u003eRelated Products\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/dsi-series-silicon-photodetectors\"\u003eDSi Series\u003c\/a\u003e — Silicon Photodetectors\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/dingaas-series-room-temperature-ingaas-detectors\"\u003eDInGaAs Series\u003c\/a\u003e — Room-Temperature InGaAs Detectors\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/dfield-nir-series-ingaas-linear-array-detectors\"\u003eDField-NIR Series\u003c\/a\u003e — InGaAs Linear Array Detectors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBrowse all: \u003ca href=\"\/collections\/lbtek-light-analysis-photodetection-spectroscopy-detectors\"\u003eSpectroscopy Detectors\u003c\/a\u003e · \u003ca href=\"\/collections\/lbtek-light-analysis-photodetection\"\u003ePhotodetection\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eModels: DInGaAs1700-TE, DInGaAs2600-TE\u003c\/strong\u003e · Contact WaveQuanta for a quote, configuration advice and lead time.\u003c\/p\u003e","brand":"WaveQuanta","offers":[{"title":"Default Title","offer_id":68106328113306,"sku":"DInGaAs-TE Series","price":0.0,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0734\/6156\/3546\/files\/wq-dingaas-te-series-te-cooled-ingaas-detectors-1.jpg?v=1794127874"},{"product_id":"dfield-nir-series-ingaas-linear-array-detectors","title":"DField-NIR Series InGaAs Linear Array Detectors, 850–2200 nm Coverage","description":"\u003cdiv class=\"wq-pdp__lbtek-desc\"\u003e\n\u003cp\u003e\u003cem\u003eInGaAs linear array detectors for multichannel near-infrared spectroscopy between 850 and 2200 nm.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eThe DField-NIR series are InGaAs linear array detectors for near-infrared spectroscopy. They combine a large dynamic range with low noise and a wide spectral response, with wavelength coverage reaching 850–2200 nm.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wq-pdp__lbtek-tips\"\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInGaAs linear array sensor for multichannel NIR detection\u003c\/li\u003e\n\u003cli\u003eWavelength coverage up to 850–2200 nm\u003c\/li\u003e\n\u003cli\u003eLarge dynamic range\u003c\/li\u003e\n\u003cli\u003eLow noise\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wq-pdp__lbtek-tips\"\u003e\n\u003ch3\u003eTypical Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNear-infrared spectroscopy on imaging spectrographs\u003c\/li\u003e\n\u003cli\u003eNIR photoluminescence measurements\u003c\/li\u003e\n\u003cli\u003eNIR absorption and transmission measurements\u003c\/li\u003e\n\u003cli\u003eMultichannel NIR spectral acquisition\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wq-pdp__lbtek-tips\"\u003e\n\u003ch3\u003eRelated Products\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/dsi-series-silicon-photodetectors\"\u003eDSi Series\u003c\/a\u003e — Silicon Photodetectors\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/dingaas-series-room-temperature-ingaas-detectors\"\u003eDInGaAs Series\u003c\/a\u003e — Room-Temperature InGaAs Detectors\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/dingaas-te-series-te-cooled-ingaas-detectors\"\u003eDInGaAs-TE Series\u003c\/a\u003e — TE-Cooled InGaAs Detectors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBrowse all: \u003ca href=\"\/collections\/lbtek-light-analysis-photodetection-spectroscopy-detectors\"\u003eSpectroscopy Detectors\u003c\/a\u003e · \u003ca href=\"\/collections\/lbtek-light-analysis-photodetection\"\u003ePhotodetection\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eModel: DField-NIR Series\u003c\/strong\u003e · Contact WaveQuanta for a quote, configuration advice and lead time.\u003c\/p\u003e","brand":"WaveQuanta","offers":[{"title":"Default Title","offer_id":68106328211610,"sku":"DField-NIR Series","price":0.0,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0734\/6156\/3546\/files\/wq-dfield-nir-series-ingaas-linear-array-detectors-1.jpg?v=1794127879"},{"product_id":"dpbs-series-room-temperature-pbs-detectors","title":"DPbS Series Room-Temperature PbS Detectors, 0.8–3.2 µm, Built-in Preamplifier","description":"\u003cdiv class=\"wq-pdp__lbtek-desc\"\u003e\n\u003cp\u003e\u003cem\u003eRoom-temperature PbS photoconductive detectors with built-in preamplifier for infrared measurements from 0.8 to 3.2 µm.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eDPbS series detectors are room-temperature lead sulfide (PbS) photoconductive detectors for the 0.8–3.2 µm infrared range. The DPbS2900 and DPbS3200 share the same construction with an integrated preamplifier, so the output is a voltage signal. As photoconductive detectors they are operated with chopped light and a lock-in amplifier.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wq-pdp__lbtek-tips\"\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTwo models: DPbS2900 (0.8–2.9 µm) and DPbS3200 (0.8–3.2 µm)\u003c\/li\u003e\n\u003cli\u003eRoom-temperature operation\u003c\/li\u003e\n\u003cli\u003eBuilt-in preamplifier with selectable gain of ×1, ×10 or ×100\u003c\/li\u003e\n\u003cli\u003eVoltage output; select voltage sampling mode when used with the DCS103 or DCS300PA data acquisition systems\u003c\/li\u003e\n\u003cli\u003eFrequency response 100–1000 Hz, with 400 Hz recommended chopping frequency\u003c\/li\u003e\n\u003cli\u003eDesigned for use with a lock-in amplifier\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wq-pdp__lbtek-tips\"\u003e\n\u003ch3\u003eTypical Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInfrared spectroscopy with scanning monochromators\u003c\/li\u003e\n\u003cli\u003eLock-in detection of chopped IR signals\u003c\/li\u003e\n\u003cli\u003eTransmission and absorption measurements from 0.8 to 3.2 µm\u003c\/li\u003e\n\u003cli\u003eInfrared photoluminescence measurements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wq-pdp__lbtek-tips\"\u003e\n\u003ch3\u003eModel Overview\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable style=\"border-collapse:collapse;width:100%;font-size:13px\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"border:1px solid #d0d7e2;padding:4px 6px;background:#f2f5f9;text-align:left\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d7e2;padding:4px 6px;background:#f2f5f9;text-align:left\"\u003eActive Area (mm)\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d7e2;padding:4px 6px;background:#f2f5f9;text-align:left\"\u003eSpectral Range (µm)\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d7e2;padding:4px 6px;background:#f2f5f9;text-align:left\"\u003ePeak Wavelength (µm)\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d7e2;padding:4px 6px;background:#f2f5f9;text-align:left\"\u003eResponsivity Su (V\/W)\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d7e2;padding:4px 6px;background:#f2f5f9;text-align:left\"\u003eDark Resistance Rd (MΩ)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003eDPbS2900\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e4 × 5\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e0.8–2.9\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e~2.2\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e~3×10⁴\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e0.2–2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003eDPbS3200\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e6 × 6\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e0.8–3.2\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e~2.1\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e~300\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e0.1–0.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wq-pdp__lbtek-tips\"\u003e\n\u003ch3\u003eRelated Products\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/dsi-series-silicon-photodetectors\"\u003eDSi Series\u003c\/a\u003e — Silicon Photodetectors\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/dingaas-series-room-temperature-ingaas-detectors\"\u003eDInGaAs Series\u003c\/a\u003e — Room-Temperature InGaAs Detectors\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/dingaas-te-series-te-cooled-ingaas-detectors\"\u003eDInGaAs-TE Series\u003c\/a\u003e — TE-Cooled InGaAs Detectors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBrowse all: \u003ca href=\"\/collections\/lbtek-light-analysis-photodetection-spectroscopy-detectors\"\u003eSpectroscopy Detectors\u003c\/a\u003e · \u003ca href=\"\/collections\/lbtek-light-analysis-photodetection\"\u003ePhotodetection\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eModels: DPbS2900, DPbS3200\u003c\/strong\u003e · Contact WaveQuanta for a quote, configuration advice and lead time.\u003c\/p\u003e","brand":"WaveQuanta","offers":[{"title":"Default Title","offer_id":68106328670362,"sku":"DPbS Series","price":0.0,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0734\/6156\/3546\/files\/wq-dpbs-series-room-temperature-pbs-detectors-1.jpg?v=1794127884"},{"product_id":"dinsb-series-liquid-nitrogen-cooled-insb-detectors","title":"DInSb Series Liquid-Nitrogen-Cooled InSb Detectors, 1–5.5 µm","description":"\u003cdiv class=\"wq-pdp__lbtek-desc\"\u003e\n\u003cp\u003e\u003cem\u003eLiquid-nitrogen-cooled InSb detectors for near- and mid-infrared spectroscopy and nanosecond time-resolved measurements.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eDInSb series detectors are liquid-nitrogen-cooled, side-window InSb photodetectors covering 1–5.5 µm. The DInSb5-De02 is a current-output detector for routine measurements with an optional preamplifier, while the DInSb5-HS adds an integrated 20 MHz preamplifier with a rise time below 25 ns for infrared time-resolved work with an oscilloscope.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wq-pdp__lbtek-tips\"\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLN2-cooled side-window InSb detectors, 1–5.5 µm\u003c\/li\u003e\n\u003cli\u003eDInSb5-De02: Ø2 mm active area as standard, with Ø1, Ø4 and Ø7 mm options\u003c\/li\u003e\n\u003cli\u003eDInSb5-HS: integrated 20 MHz preamplifier, rise time below 25 ns, for ns-scale detection with an oscilloscope\u003c\/li\u003e\n\u003cli\u003eD* of 1×10¹¹ cm·Hz½\/W at peak wavelength and 1 kHz\u003c\/li\u003e\n\u003cli\u003eHigher sensitivity with a preamplifier and lock-in amplifier (DInSb5-De02)\u003c\/li\u003e\n\u003cli\u003eDewar mounts conveniently on the spectrometer; one liquid nitrogen fill lasts about 8 hours\u003c\/li\u003e\n\u003cli\u003eFits the manual slit of Omni-λ series spectrometers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wq-pdp__lbtek-tips\"\u003e\n\u003ch3\u003eTypical Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNear- and mid-infrared spectroscopy\u003c\/li\u003e\n\u003cli\u003eInfrared time-resolved measurements\u003c\/li\u003e\n\u003cli\u003eInfrared photoluminescence\u003c\/li\u003e\n\u003cli\u003eLock-in detection of chopped IR signals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wq-pdp__lbtek-tips\"\u003e\n\u003ch3\u003eModel Overview\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable style=\"border-collapse:collapse;width:100%;font-size:13px\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"border:1px solid #d0d7e2;padding:4px 6px;background:#f2f5f9;text-align:left\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d7e2;padding:4px 6px;background:#f2f5f9;text-align:left\"\u003eActive Area (mm)\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d7e2;padding:4px 6px;background:#f2f5f9;text-align:left\"\u003ePeak Responsivity\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d7e2;padding:4px 6px;background:#f2f5f9;text-align:left\"\u003eRise Time (ns)\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d7e2;padding:4px 6px;background:#f2f5f9;text-align:left\"\u003eNEP (pW\/Hz½)\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d7e2;padding:4px 6px;background:#f2f5f9;text-align:left\"\u003eDark Current (µA)\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d7e2;padding:4px 6px;background:#f2f5f9;text-align:left\"\u003ePreamplifier\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d7e2;padding:4px 6px;background:#f2f5f9;text-align:left\"\u003eSignal Output\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003eDInSb5-De02\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003eØ2 (Ø1, Ø4, Ø7 optional)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e3 A\/W\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e–\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e1.6\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e30\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003eOptional\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003eCurrent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003eDInSb5-HS\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e1 × 1 (square)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e2×10⁴ V\/W\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003ebelow 25\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e–\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e–\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003eIntegrated, 20 MHz\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003eVoltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wq-pdp__lbtek-tips\"\u003e\n\u003ch3\u003eRelated Products\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/dsi-series-silicon-photodetectors\"\u003eDSi Series\u003c\/a\u003e — Silicon Photodetectors\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/dingaas-series-room-temperature-ingaas-detectors\"\u003eDInGaAs Series\u003c\/a\u003e — Room-Temperature InGaAs Detectors\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/dingaas-te-series-te-cooled-ingaas-detectors\"\u003eDInGaAs-TE Series\u003c\/a\u003e — TE-Cooled InGaAs Detectors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBrowse all: \u003ca href=\"\/collections\/lbtek-light-analysis-photodetection-spectroscopy-detectors\"\u003eSpectroscopy Detectors\u003c\/a\u003e · \u003ca href=\"\/collections\/lbtek-light-analysis-photodetection\"\u003ePhotodetection\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eModels: DInSb5-De02, DInSb5-HS\u003c\/strong\u003e · Contact WaveQuanta for a quote, configuration advice and lead time.\u003c\/p\u003e","brand":"WaveQuanta","offers":[{"title":"Default Title","offer_id":68106328768666,"sku":"DInSb Series","price":0.0,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0734\/6156\/3546\/files\/wq-dinsb-series-liquid-nitrogen-cooled-insb-detectors-1.jpg?v=1794127896"},{"product_id":"dmct-series-liquid-nitrogen-cooled-mct-detectors","title":"DMCT Series Liquid-Nitrogen-Cooled MCT Detectors, 2–22 µm Spectral Range","description":"\u003cdiv class=\"wq-pdp__lbtek-desc\"\u003e\n\u003cp\u003e\u003cem\u003eLiquid-nitrogen-cooled MCT detectors for mid-infrared spectroscopy and fast infrared time-resolved measurements.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eDMCT series detectors are liquid-nitrogen-cooled mercury cadmium telluride (MCT) photodetectors covering 2–22 µm. The DMCT(x)-De01 models are offered with long-wavelength cutoffs of 12, 14, 16 or 22 µm for routine measurements with a preamplifier and lock-in amplifier, while the DMCT12-HS has an integrated 20 MHz preamplifier and a rise time below 50 ns for time-resolved work.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wq-pdp__lbtek-tips\"\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDMCT(x)-De01 in four spectral ranges: 2–12, 2–14, 2–16 and 2–22 µm\u003c\/li\u003e\n\u003cli\u003eDMCT(x)-De01 models require a preamplifier and lock-in amplifier; -PA versions come with a matched preamplifier\u003c\/li\u003e\n\u003cli\u003eDMCT12-HS: integrated 20 MHz preamplifier, rise time below 50 ns, connects directly to an oscilloscope\u003c\/li\u003e\n\u003cli\u003eMinimum D* from 5×10⁹ to 3×10¹⁰ cm·Hz½\/W, depending on model\u003c\/li\u003e\n\u003cli\u003eDewar mounts conveniently on the spectrometer; one liquid nitrogen fill lasts about 8 hours\u003c\/li\u003e\n\u003cli\u003eFits the manual slit of Omni-λ series spectrometers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wq-pdp__lbtek-tips\"\u003e\n\u003ch3\u003eTypical Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMid-infrared spectroscopy\u003c\/li\u003e\n\u003cli\u003eInfrared time-resolved measurements\u003c\/li\u003e\n\u003cli\u003eInfrared emission and photoluminescence measurements\u003c\/li\u003e\n\u003cli\u003eLock-in detection of chopped IR signals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wq-pdp__lbtek-tips\"\u003e\n\u003ch3\u003eModel Overview\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable style=\"border-collapse:collapse;width:100%;font-size:13px\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"border:1px solid #d0d7e2;padding:4px 6px;background:#f2f5f9;text-align:left\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d7e2;padding:4px 6px;background:#f2f5f9;text-align:left\"\u003eSpectral Range (µm)\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d7e2;padding:4px 6px;background:#f2f5f9;text-align:left\"\u003ePeak Responsivity (V\/W)\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d7e2;padding:4px 6px;background:#f2f5f9;text-align:left\"\u003eD* min. (cm·Hz½\/W, λpeak, 1 kHz)\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d7e2;padding:4px 6px;background:#f2f5f9;text-align:left\"\u003eRise Time (ns)\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d7e2;padding:4px 6px;background:#f2f5f9;text-align:left\"\u003ePreamplifier\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003eDMCT12-De01\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e2–12\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e3×10³\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e3×10¹⁰\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e–\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003eOptional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003eDMCT14-De01\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e2–14\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e1×10³\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e3×10¹⁰\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e–\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003eOptional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003eDMCT16-De01\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e2–16\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e900\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e2.5×10¹⁰\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e–\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003eOptional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003eDMCT22-De01\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e2–22\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e150\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e5×10⁹\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e–\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003eOptional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003eDMCT12-HS\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e2–12\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003eabove 4×10⁴\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e3×10¹⁰\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003ebelow 50\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003eIntegrated, 20 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wq-pdp__lbtek-tips\"\u003e\n\u003ch3\u003eRelated Products\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/dsi-series-silicon-photodetectors\"\u003eDSi Series\u003c\/a\u003e — Silicon Photodetectors\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/dingaas-series-room-temperature-ingaas-detectors\"\u003eDInGaAs Series\u003c\/a\u003e — Room-Temperature InGaAs Detectors\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/dingaas-te-series-te-cooled-ingaas-detectors\"\u003eDInGaAs-TE Series\u003c\/a\u003e — TE-Cooled InGaAs Detectors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBrowse all: \u003ca href=\"\/collections\/lbtek-light-analysis-photodetection-spectroscopy-detectors\"\u003eSpectroscopy Detectors\u003c\/a\u003e · \u003ca href=\"\/collections\/lbtek-light-analysis-photodetection\"\u003ePhotodetection\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eModels: DMCT12-De01, DMCT14-De01, DMCT16-De01, DMCT22-De01, DMCT12-HS, DMCT12-De01-PA, DMCT14-De01-PA, DMCT16-De01-PA, DMCT22-De01-PA\u003c\/strong\u003e · Contact WaveQuanta for a quote, configuration advice and lead time.\u003c\/p\u003e","brand":"WaveQuanta","offers":[{"title":"Default Title","offer_id":68106328932506,"sku":"DMCT Series","price":0.0,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0734\/6156\/3546\/files\/wq-dmct-series-liquid-nitrogen-cooled-mct-detectors-1.jpg?v=1794127900"},{"product_id":"pmth-series-room-temperature-photomultiplier-detectors","title":"PMTH Series Room-Temperature Photomultiplier Detectors, Side-Window PMTs","description":"\u003cdiv class=\"wq-pdp__lbtek-desc\"\u003e\n\u003cp\u003e\u003cem\u003eShielded side-window PMT detectors for low-light measurements on monochromators, spectrographs and sample chambers.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003ePMTH-S1 detectors house a side-window photomultiplier tube in a light-tight enclosure with electromagnetic and optical shielding, designed to mount on Omni-λ series monochromators\/spectrographs and sample chambers. Several side-window tubes can be fitted, with spectral responses from 185 nm up to 900 nm. The matching HVC1800 high-voltage power supply provides the stable negative bias required for low-level photometry and photon counting.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wq-pdp__lbtek-tips\"\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSide-window PMT in a light-tight housing with electromagnetic and optical shielding\u003c\/li\u003e\n\u003cli\u003eMatched to Omni-λ series monochromators\/spectrographs and sample chambers\u003c\/li\u003e\n\u003cli\u003eSignal output through a standard BNC; high voltage fed through a dedicated HV-rated BNC\u003c\/li\u003e\n\u003cli\u003eCurrent output as standard, voltage output optional\u003c\/li\u003e\n\u003cli\u003eChoice of built-in tubes: CR316-02, R1527, R1527P, CR131, CR131A, R928, R2949\u003c\/li\u003e\n\u003cli\u003eOptional HVC1800 supply: 0–1500 V DC negative, set manually or by an external 0–10 V signal (e.g. from the DCS300PA)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wq-pdp__lbtek-tips\"\u003e\n\u003ch3\u003eTypical Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLow-light photometry\u003c\/li\u003e\n\u003cli\u003eSingle photon counting\u003c\/li\u003e\n\u003cli\u003eFluorescence and luminescence spectroscopy with scanning monochromators\u003c\/li\u003e\n\u003cli\u003eUV–visible spectral measurements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wq-pdp__lbtek-tips\"\u003e\n\u003ch3\u003eModel Overview\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto\"\u003e\u003ctable style=\"border-collapse:collapse;width:100%;font-size:13px\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"border:1px solid #d0d7e2;padding:4px 6px;background:#f2f5f9;text-align:left\"\u003eTube\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d7e2;padding:4px 6px;background:#f2f5f9;text-align:left\"\u003eSpectral Response (nm)\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d7e2;padding:4px 6px;background:#f2f5f9;text-align:left\"\u003ePeak Response (nm)\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d7e2;padding:4px 6px;background:#f2f5f9;text-align:left\"\u003eCathode Radiant Sens. (mA\/W)\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d7e2;padding:4px 6px;background:#f2f5f9;text-align:left\"\u003eCathode Luminous Sens. (µA\/lm)\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d7e2;padding:4px 6px;background:#f2f5f9;text-align:left\"\u003eAnode Luminous Sens. (A\/lm)\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d7e2;padding:4px 6px;background:#f2f5f9;text-align:left\"\u003eGain\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d7e2;padding:4px 6px;background:#f2f5f9;text-align:left\"\u003eAnode Dark Current Typ.\/Max. (nA)\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d7e2;padding:4px 6px;background:#f2f5f9;text-align:left\"\u003eDark Count Typ.\/Max. (cps, 25 °C)\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d7e2;padding:4px 6px;background:#f2f5f9;text-align:left\"\u003eEffective Area (mm)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003eCR316-02\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e185–650\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e340\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e48\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e40\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e–\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e1.0×10⁷\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e5 \/ 15\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e–\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e8 × 24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003eR1527\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e185–680\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e400\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e60\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e60\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e400\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e6.7×10⁶\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e0.1 \/ 2\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e–\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e8 × 24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003eR1527P\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e185–680\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e400\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e60\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e60\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e400\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e6.7×10⁶\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e0.1 \/ 0.5\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e10 \/ 50\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e8 × 24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003eCR131\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e185–900\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e400 ± 30\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e74\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e140\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e1000\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e1.0×10⁷\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e3 \/ 50\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e–\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e8 × 24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003eCR131A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e185–900\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e400 ± 30\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e74\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e250\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e1500\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e1.0×10⁷\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e3 \/ 50\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e–\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e8 × 24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003eR928\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e185–900\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e400 ± 30\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e74\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e250\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e2500\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e1.0×10⁷\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e3 \/ 50\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e–\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e8 × 24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003eR2949\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e185–900\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e400 ± 30\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e68\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e200\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e2000\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e1.0×10⁷\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e2 \/ 25\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e300 \/ 500\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d7e2;padding:4px 6px\"\u003e8 × 6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wq-pdp__lbtek-tips\"\u003e\n\u003ch3\u003eRelated Products\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/dsi-series-silicon-photodetectors\"\u003eDSi Series\u003c\/a\u003e — Silicon Photodetectors\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/dingaas-series-room-temperature-ingaas-detectors\"\u003eDInGaAs Series\u003c\/a\u003e — Room-Temperature InGaAs Detectors\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/dingaas-te-series-te-cooled-ingaas-detectors\"\u003eDInGaAs-TE Series\u003c\/a\u003e — TE-Cooled InGaAs Detectors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBrowse all: \u003ca href=\"\/collections\/lbtek-light-analysis-photodetection-spectroscopy-detectors\"\u003eSpectroscopy Detectors\u003c\/a\u003e · \u003ca href=\"\/collections\/lbtek-light-analysis-photodetection\"\u003ePhotodetection\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eModels: PMTH-S1, HVC1800\u003c\/strong\u003e · Contact WaveQuanta for a quote, configuration advice and lead time.\u003c\/p\u003e","brand":"WaveQuanta","offers":[{"title":"Default Title","offer_id":68106328998042,"sku":"PMTH Series","price":0.0,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0734\/6156\/3546\/files\/wq-pmth-series-room-temperature-photomultiplier-detectors-1.jpg?v=1794127904"},{"product_id":"dfield-vs-a4-te-cooled-spectroscopy-ccd","title":"DField-VS-A4 TE-Cooled Spectroscopy CCD, -60 °C Cooling, 30.7 mm Wide Sensor","description":"\u003cdiv class=\"wq-pdp__lbtek-desc\"\u003e\n\u003cp\u003e\u003cem\u003eDeep-cooled spectroscopy CCD that records a broad spectral band in a single exposure.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eThe DField-VS-A4 is a thermoelectrically cooled scientific CCD for spectroscopic detection. The sensor is cooled to -60 °C at 25 °C ambient and is 30.7 mm wide, so a broad wavelength band can be captured in one acquisition. It uses 15 µm pixels and reaches a peak quantum efficiency of up to 95% at 800 nm.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wq-pdp__lbtek-tips\"\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThermoelectric cooling to -60 °C at 25 °C ambient temperature\u003c\/li\u003e\n\u003cli\u003ePeak quantum efficiency up to 95% at 800 nm\u003c\/li\u003e\n\u003cli\u003e30.7 mm wide sensor captures a broad spectral band in a single shot\u003c\/li\u003e\n\u003cli\u003e15 µm pixel size for high spectral resolution\u003c\/li\u003e\n\u003cli\u003eLow dark current and low read noise\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wq-pdp__lbtek-tips\"\u003e\n\u003ch3\u003eTypical Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRaman spectroscopy\u003c\/li\u003e\n\u003cli\u003ePhotoluminescence and fluorescence spectroscopy\u003c\/li\u003e\n\u003cli\u003eLow-light spectral measurements\u003c\/li\u003e\n\u003cli\u003eMultichannel detection on imaging spectrographs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wq-pdp__lbtek-tips\"\u003e\n\u003ch3\u003eRelated Products\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/dsi-series-silicon-photodetectors\"\u003eDSi Series\u003c\/a\u003e — Silicon Photodetectors\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/dingaas-series-room-temperature-ingaas-detectors\"\u003eDInGaAs Series\u003c\/a\u003e — Room-Temperature InGaAs Detectors\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/dingaas-te-series-te-cooled-ingaas-detectors\"\u003eDInGaAs-TE Series\u003c\/a\u003e — TE-Cooled InGaAs Detectors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBrowse all: \u003ca href=\"\/collections\/lbtek-light-analysis-photodetection-spectroscopy-detectors\"\u003eSpectroscopy Detectors\u003c\/a\u003e · \u003ca href=\"\/collections\/lbtek-light-analysis-photodetection\"\u003ePhotodetection\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eModel: DField-VS-A4\u003c\/strong\u003e · Contact WaveQuanta for a quote, configuration advice and lead time.\u003c\/p\u003e","brand":"WaveQuanta","offers":[{"title":"Default Title","offer_id":68106329030810,"sku":"DField-VS-A4","price":0.0,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0734\/6156\/3546\/files\/wq-dfield-vs-a4-te-cooled-spectroscopy-ccd-1.jpg?v=1794127908"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0734\/6156\/3546\/collections\/wq-dsi-series-silicon-photodetectors-1.jpg?v=1794128328","url":"https:\/\/waveqvanta.com\/collections\/lbtek-light-analysis-photodetection-spectroscopy-detectors.oembed","provider":"WaveQuanta","version":"1.0","type":"link"}