{"title":"USB Optical Power Meters","description":"\u003cp\u003eBrowse 7+ USB optical power meters from WaveQuanta's catalog. Detailed specifications, datasheets, and 3D models available for each product. Request a quote today.\u003c\/p\u003e","products":[{"product_id":"usb-optical-power-meters-bim-7101u","title":"USB Optical Power Meters BIM-7101U","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe BIM-7101U is a USB photodiode optical power meter with a Si detector covering 380-1100 nm. It measures optical power up to ~10 mW and connects directly to a computer over USB for data acquisition, with calibration data stored in the head itself. Detachable OD attenuators extend the measurement range, and both free-space and fiber-coupled measurements are supported.\u003c\/p\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLaser power measurement and monitoring\u003c\/li\u003e\n\u003cli\u003eOptical power monitoring in semiconductor processing equipment\u003c\/li\u003e\n\u003cli\u003eInsertion-loss measurement of fibers, cables and passive optical components\u003c\/li\u003e\n\u003cli\u003eRadiation source detection\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eConstruction \u0026amp; Performance\u003c\/h3\u003e\n\u003cp\u003eThe detector uses a Si element with an effective detection diameter of 1 cm and a housing of Ø38 mm x 30 mm. Response time is ≤2 us, calibration uncertainty ±5%, and the maximum average power density without attenuator is 10 mW\/cm^2. Mounting holes (8-32 \/ M4) allow direct posting on an optical table; the connecting cable is 1.5 m and the head weighs 105 g.\u003c\/p\u003e\n\n\u003ch3\u003eStorage \u0026amp; Handling\u003c\/h3\u003e\n\u003cp\u003eOperate and store within the specified temperature and humidity range in a dry, dust-free environment. Keep the detector aperture capped when not\nin use, avoid exceeding the maximum average power density, and return the head for recalibration at regular intervals to preserve measurement accuracy.\u003c\/p\u003e","brand":"WaveQuanta","offers":[{"title":"Default Title","offer_id":48846748123290,"sku":"BIM-7101U","price":0.0,"currency_code":"SGD","in_stock":true}]},{"product_id":"usb-optical-power-meters-bim-7102u","title":"USB Optical Power Meters BIM-7102U","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe BIM-7102U is a USB photodiode optical power meter with a Si-UV detector covering 200-1100 nm. It measures optical power up to ~10 mW and connects directly to a computer over USB for data acquisition, with calibration data stored in the head itself. Detachable OD attenuators extend the measurement range, and both free-space and fiber-coupled measurements are supported.\u003c\/p\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLaser power measurement and monitoring\u003c\/li\u003e\n\u003cli\u003eOptical power monitoring in semiconductor processing equipment\u003c\/li\u003e\n\u003cli\u003eInsertion-loss measurement of fibers, cables and passive optical components\u003c\/li\u003e\n\u003cli\u003eRadiation source detection\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eConstruction \u0026amp; Performance\u003c\/h3\u003e\n\u003cp\u003eThe detector uses a Si-UV element with an effective detection diameter of 1 cm and a housing of Ø38 mm x 30 mm. Response time is ≤2 us, calibration uncertainty ±5%, and the maximum average power density without attenuator is 10 mW\/cm^2. Mounting holes (8-32 \/ M4) allow direct posting on an optical table; the connecting cable is 1.5 m and the head weighs 105 g.\u003c\/p\u003e\n\n\u003ch3\u003eStorage \u0026amp; Handling\u003c\/h3\u003e\n\u003cp\u003eOperate and store within the specified temperature and humidity range in a dry, dust-free environment. Keep the detector aperture capped when not\nin use, avoid exceeding the maximum average power density, and return the head for recalibration at regular intervals to preserve measurement accuracy.\u003c\/p\u003e","brand":"WaveQuanta","offers":[{"title":"Default Title","offer_id":48846748778650,"sku":"BIM-7102U","price":0.0,"currency_code":"SGD","in_stock":true}]},{"product_id":"usb-optical-power-meters-bim-7103u","title":"USB Optical Power Meters BIM-7103U","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe BIM-7103U is a USB photodiode optical power meter with a InGaAs detector covering 800-1650 nm. It measures optical power up to ~10 mW and connects directly to a computer over USB for data acquisition, with calibration data stored in the head itself. Detachable OD attenuators extend the measurement range, and both free-space and fiber-coupled measurements are supported.\u003c\/p\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLaser power measurement and monitoring\u003c\/li\u003e\n\u003cli\u003eOptical power monitoring in semiconductor processing equipment\u003c\/li\u003e\n\u003cli\u003eInsertion-loss measurement of fibers, cables and passive optical components\u003c\/li\u003e\n\u003cli\u003eRadiation source detection\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eConstruction \u0026amp; Performance\u003c\/h3\u003e\n\u003cp\u003eThe detector uses a InGaAs element with an effective detection diameter of 0.3 cm and a housing of Ø38 mm x 30 mm. Response time is ≤0.2 us, calibration uncertainty ±5%, and the maximum average power density without attenuator is 10 mW\/cm^2. Mounting holes (8-32 \/ M4) allow direct posting on an optical table; the connecting cable is 1.5 m and the head weighs 105 g.\u003c\/p\u003e\n\n\u003ch3\u003eStorage \u0026amp; Handling\u003c\/h3\u003e\n\u003cp\u003eOperate and store within the specified temperature and humidity range in a dry, dust-free environment. Keep the detector aperture capped when not\nin use, avoid exceeding the maximum average power density, and return the head for recalibration at regular intervals to preserve measurement accuracy.\u003c\/p\u003e","brand":"WaveQuanta","offers":[{"title":"Default Title","offer_id":48846749008026,"sku":"BIM-7103U","price":0.0,"currency_code":"SGD","in_stock":true}]},{"product_id":"usb-optical-power-meters-bim-7401u-01","title":"USB Optical Power Meters BIM-7401U-01","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe BIM-7401U-01 is a USB integrating-sphere optical power meter built around a 2 inch PTFE sphere with a Si detector covering 380-1100 nm. It measures optical power up to ~1 W and connects directly to a computer over USB, making it suitable for divergent, fiber-coupled and high-divergence sources where a bare photodiode would saturate.\u003c\/p\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLaser power measurement and monitoring\u003c\/li\u003e\n\u003cli\u003eOptical power monitoring in semiconductor processing equipment\u003c\/li\u003e\n\u003cli\u003eInsertion-loss measurement of fibers, cables and passive optical components\u003c\/li\u003e\n\u003cli\u003eRadiation source detection\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eConstruction \u0026amp; Performance\u003c\/h3\u003e\n\u003cp\u003eThe sphere provides a 12 mm entrance port and an SMA905 interface auxiliary port, with M4 \/ M6 fixing holes. Calibration uncertainty is ≤±5% and response time ≤2 us. The instrument measures 62 x 62 x 85 mm, weighs 0.5 kg and communicates over USB with a 1.5 m cable.\u003c\/p\u003e\n\n\u003ch3\u003eStorage \u0026amp; Handling\u003c\/h3\u003e\n\u003cp\u003eOperate and store within the specified temperature and humidity range in a dry, dust-free environment. Keep the detector aperture capped when not\nin use, avoid exceeding the maximum average power density, and return the head for recalibration at regular intervals to preserve measurement accuracy.\u003c\/p\u003e","brand":"WaveQuanta","offers":[{"title":"Default Title","offer_id":48846749335706,"sku":"BIM-7401U-01","price":0.0,"currency_code":"SGD","in_stock":true}]},{"product_id":"usb-optical-power-meters-bim-7402u-01","title":"USB Optical Power Meters BIM-7402U-01","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe BIM-7402U-01 is a USB integrating-sphere optical power meter built around a 2 inch PTFE sphere with a UV-Si detector covering 200-1100 nm. It measures optical power up to ~100 mW and connects directly to a computer over USB, making it suitable for divergent, fiber-coupled and high-divergence sources where a bare photodiode would saturate.\u003c\/p\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLaser power measurement and monitoring\u003c\/li\u003e\n\u003cli\u003eOptical power monitoring in semiconductor processing equipment\u003c\/li\u003e\n\u003cli\u003eInsertion-loss measurement of fibers, cables and passive optical components\u003c\/li\u003e\n\u003cli\u003eRadiation source detection\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eConstruction \u0026amp; Performance\u003c\/h3\u003e\n\u003cp\u003eThe sphere provides a 12 mm entrance port and an SMA905 interface auxiliary port, with M4 \/ M6 fixing holes. Calibration uncertainty is ≤±5% and response time ≤2 us. The instrument measures 62 x 62 x 85 mm, weighs 0.5 kg and communicates over USB with a 1.5 m cable.\u003c\/p\u003e\n\n\u003ch3\u003eStorage \u0026amp; Handling\u003c\/h3\u003e\n\u003cp\u003eOperate and store within the specified temperature and humidity range in a dry, dust-free environment. Keep the detector aperture capped when not\nin use, avoid exceeding the maximum average power density, and return the head for recalibration at regular intervals to preserve measurement accuracy.\u003c\/p\u003e","brand":"WaveQuanta","offers":[{"title":"Default Title","offer_id":48846749728922,"sku":"BIM-7402U-01","price":0.0,"currency_code":"SGD","in_stock":true}]},{"product_id":"usb-optical-power-meters-bim-7403u-01","title":"USB Optical Power Meters BIM-7403U-01","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe BIM-7403U-01 is a USB integrating-sphere optical power meter built around a 2 inch PTFE sphere with a InGaAs detector covering 800-1650 nm. It measures optical power up to ~1 W and connects directly to a computer over USB, making it suitable for divergent, fiber-coupled and high-divergence sources where a bare photodiode would saturate.\u003c\/p\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLaser power measurement and monitoring\u003c\/li\u003e\n\u003cli\u003eOptical power monitoring in semiconductor processing equipment\u003c\/li\u003e\n\u003cli\u003eInsertion-loss measurement of fibers, cables and passive optical components\u003c\/li\u003e\n\u003cli\u003eRadiation source detection\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eConstruction \u0026amp; Performance\u003c\/h3\u003e\n\u003cp\u003eThe sphere provides a 12 mm entrance port and an SMA905 interface auxiliary port, with M4 \/ M6 fixing holes. Calibration uncertainty is ≤±5% and response time ≤2 us. The instrument measures 62 x 62 x 85 mm, weighs 0.5 kg and communicates over USB with a 1.5 m cable.\u003c\/p\u003e\n\n\u003ch3\u003eStorage \u0026amp; Handling\u003c\/h3\u003e\n\u003cp\u003eOperate and store within the specified temperature and humidity range in a dry, dust-free environment. Keep the detector aperture capped when not\nin use, avoid exceeding the maximum average power density, and return the head for recalibration at regular intervals to preserve measurement accuracy.\u003c\/p\u003e","brand":"WaveQuanta","offers":[{"title":"Default Title","offer_id":48846750351514,"sku":"BIM-7403U-01","price":0.0,"currency_code":"SGD","in_stock":true}]},{"product_id":"usb-optical-power-meters-bim-7614-0250f","title":"USB Optical Power Meters BIM-7614-0250F","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe BIM-7614-0250F is a wireless thermopile laser power detector for absolute power measurement from 0.2-250 W across 0.19-20 μm. Measurement data can be read on a traditional power-meter console or transferred to a computer or mobile device over Bluetooth or USB. Each detector is individually calibrated and its calibration data is stored in the built-in EEPROM.\u003c\/p\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFiber laser power measurement\u003c\/li\u003e\n\u003cli\u003eCO2 laser power measurement\u003c\/li\u003e\n\u003cli\u003eHigh-power laser diode measurement\u003c\/li\u003e\n\u003cli\u003eExcimer laser power measurement\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eConstruction \u0026amp; Performance\u003c\/h3\u003e\n\u003cp\u003eThe thermopile absorber has an effective detection diameter of 25 mm with active air cooling. Maximum average power is 200 W (continuous); 250 W (\u0026lt;1 minute), calibration uncertainty ±5% and response time 5 s. An analog output (Output 0-5 V voltage) and external triggering are provided, and communication is available over Bluetooth, USB.\u003c\/p\u003e\n\n\u003ch3\u003eStorage \u0026amp; Handling\u003c\/h3\u003e\n\u003cp\u003eOperate and store within the specified temperature and humidity range in a dry, dust-free environment. Keep the detector aperture capped when not\nin use, avoid exceeding the maximum average power density, and return the head for recalibration at regular intervals to preserve measurement accuracy.\u003c\/p\u003e","brand":"WaveQuanta","offers":[{"title":"Default Title","offer_id":48846750711962,"sku":"BIM-7614-0250F","price":0.0,"currency_code":"SGD","in_stock":true}]}],"url":"https:\/\/waveqvanta.com\/collections\/lbtek-light-analysis-power-energy-meters-usb-optical-power-meters.oembed","provider":"WaveQuanta","version":"1.0","type":"link"}