{"title":"Single-axis Scanning Micromirrors","description":"\u003cp\u003eBrowse 4+ mirrors from WaveQuanta's catalog. Detailed specifications, datasheets, and 3D models available for each product. Request a quote today.\u003c\/p\u003e","products":[{"product_id":"single-axis-scanning-micromirrors-mems-12-0-2k","title":"Single-axis Scanning Micromirrors MEMS-12-0.2K","description":"\u003cp\u003eThe Single-axis Scanning Micromirrors MEMS-12-0.2K from WaveQuanta is a high-performance Stages Actuators designed for micrometer-precision optical alignment and positioning. Key specification: design wavelength: 800 nm-20 μm. Available from stock for immediate shipment. Sourced directly from WaveQuanta, this product meets the high standards required for scientific research and precision photonics applications.\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #16a34a;\"\u003e✔ In Stock — Ships Today\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cdiv class=\"wq-pdp__lbtek-desc\"\u003eThe single-axis scanning micromirror provided by LBTEK is a chip based on MEMS technology, where the MEMS-1.3-1.15K is electrostatically driven and the MEMS-12-0.2K is electromagnetically driven. Under the action of the driving signal, the micromirror performs resonant torsional motion around the torsion beam to achieve the effect of single-axis scanning. The micromirror is processed from single-crystal silicon and coated with a metal film on the mirror surface to increase reflectivity. The mirror itself is supported by torsion beams and performs resonant motion under the driving signal (it cannot stop at a certain angle, and the frequency cannot be adjusted). For product parameters and usage, users can download the manual for reference.\n\nNote: To extend the product's service life, minimize the number of insertions and removals between the development board and the flexible cable of the single-axis scanning micromirror during use to avoid damaging the data interface (once damaged, it cannot be repaired).\u003c\/div\u003e\n\n\u003cdiv class=\"wq-pdp__lbtek-tips\"\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eLarge scanning angle\u003c\/li\u003e\n  \u003cli\u003eSingle-axis scanning with high linearity\u003c\/li\u003e\n  \u003cli\u003eDevelopment board control with visual operation\u003c\/li\u003e\n  \u003cli\u003eRefer to technical specifications for real-time angle calculation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"wq-pdp__lbtek-explain\"\u003e\n\u003ch3\u003eApplication\u003c\/h3\u003e\n\u003cp\u003eInstall a single-axis scanning micromirror using AMP-1R\u003c\/p\u003e\n\u003c\/div\u003e","brand":"WaveQuanta","offers":[{"title":"Default Title","offer_id":47499631657114,"sku":"MEMS-12-0.2K","price":2179.61,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0734\/6156\/3546\/files\/092ed0e745b15265301dcd2f392264a7.jpg?v=1772282276"},{"product_id":"single-axis-scanning-micromirrors-mems-1-3-1-15k","title":"Single-axis Scanning Micromirrors MEMS-1.3-1.15K","description":"\u003cp\u003e\u003cstrong\u003eSingle-axis Scanning Micromirrors MEMS-1.3-1.15K\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"color: #16a34a;\"\u003e✔ In Stock — Ships Today\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cdiv class=\"wq-pdp__lbtek-desc\"\u003eThe single-axis scanning micromirror provided by LBTEK is a chip based on MEMS technology, where the MEMS-1.3-1.15K is electrostatically driven and the MEMS-12-0.2K is electromagnetically driven. Under the action of the driving signal, the micromirror performs resonant torsional motion around the torsion beam to achieve the effect of single-axis scanning. The micromirror is processed from single-crystal silicon and coated with a metal film on the mirror surface to increase reflectivity. The mirror itself is supported by torsion beams and performs resonant motion under the driving signal (it cannot stop at a certain angle, and the frequency cannot be adjusted). For product parameters and usage, users can download the manual for reference.\n\nNote: To extend the product's service life, minimize the number of insertions and removals between the development board and the flexible cable of the single-axis scanning micromirror during use to avoid damaging the data interface (once damaged, it cannot be repaired).\u003c\/div\u003e\n\n\u003cdiv class=\"wq-pdp__lbtek-tips\"\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eLarge scanning angle\u003c\/li\u003e\n  \u003cli\u003eSingle-axis scanning with high linearity\u003c\/li\u003e\n  \u003cli\u003eDevelopment board control with visual operation\u003c\/li\u003e\n  \u003cli\u003eRefer to technical specifications for real-time angle calculation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"wq-pdp__lbtek-explain\"\u003e\n\u003ch3\u003eApplication\u003c\/h3\u003e\n\u003cp\u003eInstall a single-axis scanning micromirror using AMP-1R\u003c\/p\u003e\n\u003c\/div\u003e","brand":"WaveQuanta","offers":[{"title":"Default Title","offer_id":47499631722650,"sku":"MEMS-1.3-1.15K","price":817.42,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0734\/6156\/3546\/files\/092ed0e745b15265301dcd2f392264a7_62697cd1-7dc6-45fc-abd4-504ef45fe35f.jpg?v=1772282276"},{"product_id":"single-axis-scanning-micromirrors-mddb-12-0-2k","title":"Single-axis Scanning Micromirrors MDDB-12-0.2K","description":"\u003cp\u003eThe Single-axis Scanning Micromirrors MDDB-12-0.2K from WaveQuanta is a high-performance Stages Actuators designed for micrometer-precision optical alignment and positioning. Available from stock for immediate shipment. Sourced directly from WaveQuanta, this product meets the high standards required for scientific research and precision photonics applications.\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #16a34a;\"\u003e✔ In Stock — Ships Today\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cdiv class=\"wq-pdp__lbtek-desc\"\u003eThe single-axis scanning micromirror development board provided by LBTEK can be used for scanning control of single-axis scanning micromirrors, featuring visual operation and precise control, with the ability to read the mirror status in real time. The development board is powered via a Micro-USB interface and does not require an external power supply. Users can select the appropriate development board based on the purchased single-axis scanning micromirror.  \nNote: The development board is an unencapsulated PCB circuit board and should not be placed directly on the surface of an optical platform during use.\u003c\/div\u003e\n\n\u003cdiv class=\"wq-pdp__lbtek-tips\"\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eIntegrated development board, easy to operate\u003c\/li\u003e\n  \u003cli\u003eMicro-USB power supply interface\u003c\/li\u003e\n  \u003cli\u003eReal-time scanning status reading\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"wq-pdp__lbtek-explain\"\u003e\n\u003ch3\u003eApplication\u003c\/h3\u003e\n\u003cp\u003eSingle-axis scanning micromirror development board\u003c\/p\u003e\n\u003c\/div\u003e","brand":"WaveQuanta","offers":[{"title":"Default Title","offer_id":47499631755418,"sku":"MDDB-12-0.2K","price":272.65,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0734\/6156\/3546\/files\/893e98a07249631ab3f4c1152e553e08.jpg?v=1772282278"},{"product_id":"single-axis-scanning-micromirrors-mddb-1-3-1-15k","title":"Single-axis Scanning Micromirrors MDDB-1.3-1.15K","description":"\u003cp\u003e\u003cstrong\u003eSingle-axis Scanning Micromirrors MDDB-1.3-1.15K\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"color: #16a34a;\"\u003e✔ In Stock — Ships Today\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cdiv class=\"wq-pdp__lbtek-desc\"\u003eThe single-axis scanning micromirror development board provided by LBTEK can be used for scanning control of single-axis scanning micromirrors, featuring visual operation and precise control, with the ability to read the mirror status in real time. The development board is powered via a Micro-USB interface and does not require an external power supply. Users can select the appropriate development board based on the purchased single-axis scanning micromirror.  \nNote: The development board is an unencapsulated PCB circuit board and should not be placed directly on the surface of an optical platform during use.\u003c\/div\u003e\n\n\u003cdiv class=\"wq-pdp__lbtek-tips\"\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eIntegrated development board, easy to operate\u003c\/li\u003e\n  \u003cli\u003eMicro-USB power supply interface\u003c\/li\u003e\n  \u003cli\u003eReal-time scanning status reading\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"wq-pdp__lbtek-explain\"\u003e\n\u003ch3\u003eApplication\u003c\/h3\u003e\n\u003cp\u003eSingle-axis scanning micromirror development board\u003c\/p\u003e\n\u003c\/div\u003e","brand":"WaveQuanta","offers":[{"title":"Default Title","offer_id":47499631820954,"sku":"MDDB-1.3-1.15K","price":272.65,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0734\/6156\/3546\/files\/893e98a07249631ab3f4c1152e553e08_75b8a49b-4688-42be-95ab-52f1182f118d.jpg?v=1772282279"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0734\/6156\/3546\/collections\/893e98a07249631ab3f4c1152e553e08_75b8a49b-4688-42be-95ab-52f1182f118d.jpg?v=1777788279","url":"https:\/\/waveqvanta.com\/collections\/lbtek-motion-control-electric-optical-stages-single-axis-scanning-micromirrors.oembed","provider":"WaveQuanta","version":"1.0","type":"link"}