{"title":"X-ray Cameras","description":"\u003cp\u003eBrowse 4+ cameras from WaveQuanta's catalog. Detailed specifications, datasheets, and 3D models available for each product. Request a quote today.\u003c\/p\u003e","products":[{"product_id":"sophia-xo-soft-x-ray-ccd-camera","title":"SOPHIA-XO Soft X-ray CCD Camera","description":"\u003cp\u003eThe SOPHIA-XO is a high-performance CCD camera optimized for direct soft X-ray and EUV detection. Featuring a back-illuminated, back-thinned CCD sensor in a permanent vacuum enclosure, it achieves quantum efficiency \u0026gt;80% in the soft X-ray range (10 eV - 20 keV). The sensor operates at -70°C via thermoelectric cooling with no cryogens required. Available in multiple sensor formats up to 2048×2048.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDirect soft X-ray and EUV detection\u003c\/li\u003e\n\u003cli\u003ePermanent vacuum enclosure\u003c\/li\u003e\n\u003cli\u003eBack-illuminated, back-thinned CCD\u003c\/li\u003e\n\u003cli\u003eQE \u0026gt;80% in soft X-ray range\u003c\/li\u003e\n\u003cli\u003eThermoelectric cooling to -70°C\u003c\/li\u003e\n\u003cli\u003eNo cryogens required\u003c\/li\u003e\n\u003cli\u003eSingle-photon energy resolution\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eX-ray spectroscopy\u003c\/li\u003e\n\u003cli\u003eSynchrotron beamline imaging\u003c\/li\u003e\n\u003cli\u003eEUV lithography characterization\u003c\/li\u003e\n\u003cli\u003ePlasma diagnostics\u003c\/li\u003e\n\u003cli\u003eX-ray crystallography\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable style=\"border-collapse: collapse; width: 100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background: #f3f4f6;\"\u003e\n\u003cth style=\"text-align: left; padding: 8px; border: 1px solid #e5e7eb;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"text-align: left; padding: 8px; border: 1px solid #e5e7eb;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003eWavelength Range Min\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003e0.06 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003eWavelength Range Max\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003e124.0 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003eSensor Type\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003eBack-Thinned CCD (Vacuum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003ePixel Size\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003e15.0 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003e2048x2048 px\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003eFrame Rate\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003e1.0 fps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003eCooling Method\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003eThermoelectric (Vacuum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003eCooling Temperature\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003e-70.0 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003eSpectral Range\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003e10eV-20keV (0.06-124nm) nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003eQuantum Efficiency\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003e80.0 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003eDark Current\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003e0.0005 e⁻\/px\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003e6.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"margin-top: 16px; font-size: 0.85em; color: #6b7280;\"\u003eSource: \u003ca href=\"https:\/\/www.teledynevisionsolutions.com\/products\/sophia_xo\/?vertical=tvs-princeton-instruments\u0026amp;segment=tvs\" target=\"_blank\"\u003ePrinceton Instruments Product Page\u003c\/a\u003e\u003c\/p\u003e","brand":"Princeton Instruments","offers":[{"title":"Default Title","offer_id":47482662453402,"sku":"PI-SOPHIA-XO-2048","price":0.0,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0734\/6156\/3546\/files\/sophia-xo-5--prc-refl-500px.png?v=1772025994"},{"product_id":"pixis-xo-soft-x-ray-ccd-camera","title":"PIXIS-XO Soft X-ray CCD Camera","description":"\u003cp\u003eThe PIXIS-XO is a vacuum-compatible, thermoelectrically cooled CCD camera for direct soft X-ray and EUV detection. The back-thinned sensor in a permanent vacuum housing provides high quantum efficiency across the soft X-ray spectrum without the need for phosphor coatings. TE cooling to -70°C eliminates cryogen logistics in beamline environments.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDirect soft X-ray detection (no phosphor)\u003c\/li\u003e\n\u003cli\u003ePermanent vacuum enclosure\u003c\/li\u003e\n\u003cli\u003eBack-thinned CCD sensor\u003c\/li\u003e\n\u003cli\u003eThermoelectric cooling to -70°C\u003c\/li\u003e\n\u003cli\u003eNo cryogens required\u003c\/li\u003e\n\u003cli\u003eMultiple sensor formats\u003c\/li\u003e\n\u003cli\u003eBeamline-compatible design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSynchrotron soft X-ray imaging\u003c\/li\u003e\n\u003cli\u003eEUV characterization\u003c\/li\u003e\n\u003cli\u003eX-ray absorption spectroscopy\u003c\/li\u003e\n\u003cli\u003ePlasma diagnostics\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable style=\"border-collapse: collapse; width: 100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background: #f3f4f6;\"\u003e\n\u003cth style=\"text-align: left; padding: 8px; border: 1px solid #e5e7eb;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"text-align: left; padding: 8px; border: 1px solid #e5e7eb;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003eWavelength Range Min\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003e0.06 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003eWavelength Range Max\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003e124.0 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003eSensor Type\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003eBack-Thinned CCD (Vacuum, TE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003ePixel Size\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003e13.5 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003e2048x2048 px\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003eFrame Rate\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003e2.0 fps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003eCooling Method\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003eThermoelectric (Vacuum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003eCooling Temperature\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003e-70.0 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003eSpectral Range\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003e10eV-20keV nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003eQuantum Efficiency\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003e80.0 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003eDark Current\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003e0.001 e⁻\/px\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003e5.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"margin-top: 16px; font-size: 0.85em; color: #6b7280;\"\u003eSource: \u003ca href=\"https:\/\/www.teledynevisionsolutions.com\/products\/pixis-xo\/?vertical=tvs-princeton-instruments\u0026amp;segment=tvs\" target=\"_blank\"\u003ePrinceton Instruments Product Page\u003c\/a\u003e\u003c\/p\u003e","brand":"Princeton Instruments","offers":[{"title":"Default Title","offer_id":47482662879386,"sku":"PI-PIXIS-XO-2048","price":0.0,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0734\/6156\/3546\/files\/pixis-ox-shadow-vingette2--prc-refl-500px.png?v=1772026022"},{"product_id":"pi-mte3-thermoelectric-x-ray-ccd-camera","title":"PI-MTE3 Thermoelectric X-ray CCD Camera","description":"\u003cp\u003eThe PI-MTE3 is a 3-stage thermoelectrically cooled CCD camera for X-ray imaging. Cooling to -85°C without cryogens, combined with large-format sensors up to 2048×2048, makes it ideal for X-ray diffraction, scattering, and crystallography. Direct detection provides excellent energy resolution while the deep cooling minimizes thermal noise for long exposures.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e3-stage TE cooling to -85°C\u003c\/li\u003e\n\u003cli\u003eNo cryogens required\u003c\/li\u003e\n\u003cli\u003eLarge-format sensors up to 2048×2048\u003c\/li\u003e\n\u003cli\u003eDirect X-ray detection\u003c\/li\u003e\n\u003cli\u003eLow read noise for X-ray energy resolution\u003c\/li\u003e\n\u003cli\u003eUSB interface\u003c\/li\u003e\n\u003cli\u003eCompact design for beamline integration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eX-ray diffraction\u003c\/li\u003e\n\u003cli\u003eSmall-angle X-ray scattering (SAXS)\u003c\/li\u003e\n\u003cli\u003eX-ray crystallography\u003c\/li\u003e\n\u003cli\u003eX-ray imaging\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable style=\"border-collapse: collapse; width: 100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background: #f3f4f6;\"\u003e\n\u003cth style=\"text-align: left; padding: 8px; border: 1px solid #e5e7eb;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"text-align: left; padding: 8px; border: 1px solid #e5e7eb;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003eWavelength Range Min\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003e0.01 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003eWavelength Range Max\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003e10.0 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003eSensor Type\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003eCCD (3-Stage TE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003ePixel Size\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003e13.5 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003e2048x2048 px\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003eFrame Rate\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003e1.0 fps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003eCooling Method\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003eThermoelectric (3-Stage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003eCooling Temperature\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003e-85.0 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003eSpectral Range\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003e1-120keV nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003eQuantum Efficiency\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003e90.0 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003eDark Current\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003e0.0001 e⁻\/px\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003e5.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"margin-top: 16px; font-size: 0.85em; color: #6b7280;\"\u003eSource: \u003ca href=\"https:\/\/www.teledynevisionsolutions.com\/products\/pi_mte3\/?vertical=tvs-princeton-instruments\u0026amp;segment=tvs\" target=\"_blank\"\u003ePrinceton Instruments Product Page\u003c\/a\u003e\u003c\/p\u003e","brand":"Princeton Instruments","offers":[{"title":"Default Title","offer_id":47482662977690,"sku":"PI-MTE3-2048","price":0.0,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0734\/6156\/3546\/files\/pi-met3-1--prc-refl-500px.png?v=1772026032"},{"product_id":"lansis-large-area-soft-x-ray-imager","title":"LANSIS Large Area Soft X-ray Imager","description":"\u003cp\u003eThe LANSIS (Large Area Near-field Soft-x-ray Imager System) is a specialized large-format CCD camera for soft X-ray and EUV imaging. Featuring a vacuum-compatible, back-thinned sensor with up to 4096×4096 pixels, it provides the largest imaging area in its class for synchrotron and FEL beamline applications. Available in 2048F, 2048B, and 4096 formats.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eLarge-format sensors up to 4096×4096\u003c\/li\u003e\n\u003cli\u003eVacuum-compatible back-thinned CCD\u003c\/li\u003e\n\u003cli\u003eDirect soft X-ray detection\u003c\/li\u003e\n\u003cli\u003eHigh spatial resolution\u003c\/li\u003e\n\u003cli\u003eDesigned for beamline applications\u003c\/li\u003e\n\u003cli\u003eMultiple readout configurations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSynchrotron beamlines\u003c\/li\u003e\n\u003cli\u003eFree-electron laser (FEL) experiments\u003c\/li\u003e\n\u003cli\u003eEUV mask inspection\u003c\/li\u003e\n\u003cli\u003eSoft X-ray microscopy\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable style=\"border-collapse: collapse; width: 100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background: #f3f4f6;\"\u003e\n\u003cth style=\"text-align: left; padding: 8px; border: 1px solid #e5e7eb;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"text-align: left; padding: 8px; border: 1px solid #e5e7eb;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003eWavelength Range Min\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003e0.06 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003eWavelength Range Max\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003e124.0 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003eSensor Type\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003eBack-Thinned CCD (Vacuum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003ePixel Size\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003e15.0 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003e2048x2048 px\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003eFrame Rate\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003e0.5 fps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003eCooling Method\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003eThermoelectric (Vacuum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003eCooling Temperature\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003e-60.0 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003eSpectral Range\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003e10eV-20keV nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003eQuantum Efficiency\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003e80.0 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px; border: 1px solid #e5e7eb;\"\u003e10.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"margin-top: 16px; font-size: 0.85em; color: #6b7280;\"\u003eSource: \u003ca href=\"https:\/\/www.teledynevisionsolutions.com\/products\/lansis\/?vertical=tvs-princeton-instruments\u0026amp;segment=tvs\" target=\"_blank\"\u003ePrinceton Instruments Product Page\u003c\/a\u003e\u003c\/p\u003e","brand":"Princeton Instruments","offers":[{"title":"Default Title","offer_id":47482664386714,"sku":"PI-LANSIS-2048","price":0.0,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0734\/6156\/3546\/files\/lansis-261noback--prc-refl-500px.png?v=1772026038"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0734\/6156\/3546\/collections\/lansis-261noback--prc-refl-500px.png?v=1777788424","url":"https:\/\/waveqvanta.com\/collections\/wq-pi-xray-cameras.oembed","provider":"WaveQuanta","version":"1.0","type":"link"}