Fluorescence Dichroic Mirrors, Rectangular DMR-600LP
DMR-600LPDesign Tools
View all 49 calculators →Fluorescence Dichroic Mirrors, Rectangular — Model DMR-600LP
UVFS fluorescence dichroic mirror for mChery, 36.0 mm×25.0 mm, reflection band 500-590 nm, transmission band 610-850 nm, 45° AOI.
Overview
Fluorescence Dichroic Mirrors adopt a high-performance UV Fused Silica (UVFS) substrate, specifically designed for 45° oblique incidence optical paths. They feature high reflection in the short-wave range and high transmission in the long-wave range, enabling precise separation of optical path signals. The purified excitation light is reflected to excite the sample, while specific fluorescence signals are efficiently transmitted, ensuring a highly efficient and lossless optical path. The products have accurate spectral calibration, no crosstalk, and no stray reflections. Each model can be precisely matched with corresponding filter sets. Fluorescence Dichroic Mirrors come in a standard size of 36.0 mm x 25.0 mm x 1.0 mm, compatible with mainstream filter cubes, coaxial optical paths, and microscope modules. Both surfaces of the dichroic mirror are coated with a filter coating and an antireflection coating. The arrow (<) on the side points to the filter-coated surface. During use, light should enter from the filter-coated surface.
Key Features
- fluorescent dye: mChery
- Reflection band: 500-590 nm
- Transmission band: 610-850 nm
- Reflectivity: Ravg>95%
- Transmittance: Tavg>95%
- Size: 36.0 mm×25.0 mm
- Thickness: 1.0 mm
- Clear Aperture: >32.4 mm×22.5 mm
- Angle of Incidence (AOI): 45°
- Transmitted Wavefront Error (TWE) (@633 nm): λ/2
- Surface Quality (Scratch/Dig): 60/40
- Parallelism: <3 arcmin
- Material: UVFS
Applications
- Fluorescence microscopy: reflects the excitation light to the sample and transmits the fluorescence emission
- Filter cubes, coaxial optical paths and microscope modules (matched with the corresponding filter sets)
| Thickness | 1.0 mm |
| Clear Aperture | >32.4 mm×22.5 mm |
| Material | UVFS |
| Thickness Tolerance | ±0.1 mm |
| Reflectivity | Ravg>95% |
| Surface Quality (Scratch/Dig) | 60/40 |
| Transmission band | 610-850 nm |
| Reflection band | 500-590 nm |
| Transmitted Wavefront Error (TWE) (@633 nm) | λ/2 |
| Parallelism | <3 arcmin |
| Angle of Incidence (AOI) | 45° |
| Size | 36.0 mm×25.0 mm |
| Dimensional tolerance | +0.0/-0.1 mm |
| fluorescent dye | mChery |
| Transmittance | Tavg>95% |
| Anti-reflection coating reflectivity | Rabs<2%@610-850 nm |
| Operating Temperature | -40°C~+90°C |